10. Technical Data; Ambient Conditions; Use; Storage And Transportation - Bosch VLH 2155 Manual Original

Elevador de dos columnas
Ocultar thumbs Ver también para VLH 2155:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
en
34 | VLH 2155 | Technical data

10. Technical data

10.1

Ambient conditions

10.1.1

Use

Property
Temperature
Humidity
10.1.2

Storage and transportation

Property
Temperature
Humidity
10.2

Performance data

10.2.1

Lifting platform

Property
Loadbearing capacity
Lifting height
Lifting time
Drive-on height
10.3

Operating data

10.3.1

Electric power

Property
Rated voltage (DC)
Rated current
Rated power
Operating factor
Frequency
Number of phases
Control voltage
Fuse protection
Current, highest load
Degree of protection
Safety class
10.3.2

Pneumatic system

Property
Pneumatic locking
|
1 689 989 141
2017-05-08
10.3.3
Property
Cylinder operating pressure
Pump delivery
Value/Range
Filling volume
Extraction volume
5 °C – 45 °C
41 °F – 113 °F
Fluid type
20 % - 80 %
10.4
Feature
Value/Range
Sound pressure level as per
DIN EN ISO 3744
-25 °C – 45 °C
-13 °F – 113 °F
30 % – 60 %
10.5
The VLH 2155 satisfies the requirements of the EMC
directive 2014/130/EU.
i
The VLH 2155 is a class/category A product as defi-
Value/Range
ned by EN 61 326. The VLH 2155 may cause high-fre-
5500 kg
quency household interference (radio interference)
1985 mm
so that interference suppression may be necessary.
48 s
In such cases the user may be required to take the
185 mm
appropriate action.
Value/Range
400 V
6.7 A
3.0 kW
S3 -10 %
50 Hz
3PE
230 V AC
20/3/B
16 A
IP 54
/ II
Value/Range
8 bar

Hydraulic system

Noise emissions

Electromagnetic compatibility (EMC)

Value/Range
180 bar (18 MPa)
10 l/min
9.5 l
7.9 l
Hydraulic fluid
Value/Range
74 dB(A)
Robert Bosch GmbH

Publicidad

Tabla de contenido
loading

Tabla de contenido