Operating instructions SATAjet 4000 B RP/HVLP
Malfunction
Round/flat spray con-
trol cannot be regu-
lated
Spray gun does not
shut-off air
Corrosion on air cap
thread, inside material
passages (cup con-
nection) or on spray
gun body
Material leaks from
behind the paint nee-
dle sealing
Spray gun leaks from
the fluid tip ("fluid tip
aperture")
11. Disposal
Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!
12. After Sale Service
Accessories, spare parts and technical support may be obtained from
your SATA dealer.
Cause
Regulation valve dirty
Clogged air piston seat
or worn air piston.
Cleaning solution
(water-based) remains
inside/on the spray
gun for too long.
Unsuitable cleaning
solutions
Defective or missing
paint needle sealing.
Clogged or damaged
paint needle.
Contamination be-
tween paint needle tip
and fluid tip
Damaged nozzle set.
Corrective Action
Remove round/flat
spray control, repair or
replace it, chapter 9.7
Clean air piston seat
and/or replace air pis-
ton, air piston packing,
chapter 9.4
Cleaning, observe
chapter 8, get a
replacement spray
gun body.
Replace / insert paint
needle sealing, chap-
ter 9.3
Replace nozzle set,
chapter 9.1; replace
paint needle sealing, if
necessary, chapter 9.3
Clean fluid tip and
paint needle, observe
chapter 8
Replace nozzle set,
chapter 9
EN
111