Specification
Loop resistance (HART
communications)
Loop resistance (non-HART
communications)
HART burst mode
HART protocol revision
Certification
Section 3 General information
In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer's website.

3.1 Safety information

The manufacturer is not responsible for any damages due to misapplication or misuse of this
product including, without limitation, direct, incidental and consequential damages, and disclaims
such damages to the full extent permitted under applicable law. The user is solely responsible to
identify critical application risks and install appropriate mechanisms to protect processes during a
possible equipment malfunction.
Please read this entire manual before unpacking, setting up or operating this equipment. Pay
attention to all danger and caution statements. Failure to do so could result in serious injury to the
operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this
equipment in any manner other than that specified in this manual.

3.1.1 Use of hazard information

Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or
serious injury.
Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death
or serious injury.
Indicates a potentially hazardous situation that may result in minor or moderate injury.
Indicates a situation which, if not avoided, may cause damage to the instrument. Information that
requires special emphasis.
4 English
Details
Internal module loop power: 250–350 Ω
18–24 VDC power supply: 250–500 Ω
24–30 VDC power supply: 250–976 Ω
Internal module loop power: 0–350 Ω
12–24 VDC power supply: 0–250 Ω
24–30 VDC power supply: 250–976 Ω
Not supported
7.2
Class I, Division 2 Groups A, B, C, D and Class I, Zone
2 Group IIC, T4 Hazardous and Ordinary Locations
N O T I C E
D A N G E R
W A R N I N G
C A U T I O N
N O T I C E