Transport And Interim Storage - Wilo MVIL Serie Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para MVIL Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
English
2.6 Unauthorised modification and manufacture of
spare parts
Changes to the pump/machinery may only be
made in agreement with the manufacturer.
The use of original spare parts and accessories
authorised by the manufacturer will ensure safe-
ty. The use of any other parts may invalidate
claims invoking the liability of the manufacturer
for any consequences.
2.7
Improper use
The operating safety of the pump or installation
can only be guaranteed if it is used in accordance
with paragraph 4 of the operating instructions.
All values must neither exceed nor fall below the
limit values given in the catalogue or data sheet.

3. Transport and interim storage

When receiving the material, check that there has
been no damage during the transport. If any defect
has been stated, take the required steps with the
carrier within the allowed time. If the delivered
material is to be installed later on, store it in a dry
place and protect it from impacts and any outside
influences (humidity, frost etc...).
DANGER! Due to high position of centre of gravity
and small ground surface of this type of pumps,
beware of unstability during handling to avoid any
falling down and take necessary means to avoid
injuries or damaging.
CAUTION! Handle the pump carefully so as not
to alter the geometry and the alignment of the
hydraulic unit.
4. Products and accessories
4.1 Description (fig. 1, 2, 5):
1 - Strainer-foot valve
2 - Pump suction valve
3 - Pump discharge valve
4 - Non-return valve
5 - Venting and filling plug
6 - Drain-priming plug
7 - Pipe supports
8 - Strainer
9 - Storage tank
10 - Town water supply
11 - Motor overload release
12 - Foundation block
13 - Cock
HA - Maximum suction head
HC - Minimum inlet pressure
4.2 The pump
Vertical multistage pump (2 to 12 stages) not
self-priming, with ports in line on the same axis
at the bottom part.
Shaft tightness with standard mechanical seal.
Oval Flanges for PN 16 pump casing: pump deliv-
ered with oval counterflanges in cast iron for
screw-on tube, gaskets and bolts.
12
4.3 The motor
Dry motor - 2 poles.
Protection index: IP 54
Insulation class: F
Single phase motor:
- With integrated thermal protection, automatic
reset.
- Capacitor integrated inside the terminal box.
FREQUENCY
50Hz
Speed RPM
2900
Winding* TRI ≤4
230/400 V 220/380V to 254/ 440V
* Standard voltage motors: on network (50Hz) ± 10%
- (60Hz) ± 6%
Maximun number of starts per hour
Motor Power (kW)
0,37 0,55 0,75 1,1
Direct
100
90
4.4 Accessories (as option)
• By-pass kit • isolating valves • bladder or gal-
vanised tank • tank for antihammer blow effect
• control box • PN 25 weld-on counter-flange
(steel) or tapped (stainless steel) • tapped oval
counter-flange PN 16 in stainless steel - motor
overload release • non-return valves • strainer-
foot valve • vibrationless sleeves • dry-running
protection kit • flexible collar type Victaulic style
77 • threaded muff joint (stainless steel)...
5. INSTALLATION
Two standard cases:
• fig. 1: pump in suction
• fig. 2: pump under pressure on storage tank (9) or town
water supply (10) with dry-running protection system.
5.1 Montage
Install the pump in a place easy to reach,protect-
ed against frost and as close as possible from the
drawing point.
Install the pump on a concrete block (at least
10 cm high) (fig. 12) and fix with anchor bolts
(installation plan fig. 3).
Foresee an isolating material under the concrete
block (cork or reinforced rubber) to avoid any
noise and vibration transmission into the instal-
lation.
Before final tightening of anchor bolts, ensure that
the pump axis is vertical: use shims if necessary.
Bear in mind that the altitude of the installation
place and water temperature may reduce the
suction head of the pump.
Loss of head
Altitude
0 m
0 mCL
500 m
0,60 mCL
1000 m
1,15 mCL
1500 m
1,70 mCL
2000 m
2,20 mCL
2500 m
2,65 mCL
3000 m
3,20 mCL
60Hz
3500
1,5
1,85 2,2
2,5
75
60
50
45
40
40
Loss of head
Temperature
20 °C
0,20 mCL
30 °C
0,40 mCL
40 °C
0,70 mCL
50 °C
1,20 mCL
60 °C
1,90 mCL
70 °C
3,10 mCL
80 °C
4,70 mCL
90 °C
7,10 mCL
100 °C
10,30 mCL
WILO SE 04/2019

Publicidad

Tabla de contenido
loading

Tabla de contenido