SATA jet 1000 K RP Instrucciones De Servicio página 138

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 147
Operating Instructions SATAjet 1000 K (RP / HVLP) / H (RP)
EN
■ Insert air distribution ring. The pin [8-3] of the air distribution ring must
be aligned accordingly.
■ Press the air distribution ring in evenly.
■ Mount nozzle set (see chapter 9.1).
After installation, adjust the material flow according to chapter 8.2.
9.3. Replace paint needle seal
This must be replaced when material leaks from the self-adjusting paint
needle packing.
Dismantle paint needle seal
■ Loosen counter nut [1-3].
■ Screw adjusting screw [1-2] with counter nut out of the gun body.
■ Remove spring and paint needle [9-1].
■ Remove the trigger guard [9-2].
■ Screw the paint needle seal [9-3] out of the gun body.
Mount paint needle seal
■ Screw the paint needle seal [9-3] into the gun body.
■ Mount the trigger guard [9-2].
■ Insert spring and paint needle [9-1].
■ Screw adjusting screw [1-2] with counter nut [1-3] into the gun body.
After installation, adjust the material flow according to chapter 8.2.
9.4. Replace air piston, air piston spring and air
micrometer
Risk of injuries from air micrometer coming loose.
When the locking screw is not screwed tight, the air micrometer can
shoot uncontrolled out of the spray gun.
→ Check that the locking screw of the air micrometer fits firmly and 
tighten if necessary.
Replacement is necessary if
air escapes at the air cap or air micrometer without actuating the trigger
guard.
Dismantle air piston, air piston spring and air micrometer
■ Screw the locking screw [10-1] out of the gun body.
138
Warning!

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jet 1000 k hvlpJet 1000 h rp

Tabla de contenido