MOVING PARTS HAZARD;
page 4.
1. Keep all screws, nuts, washers, gaskets, and
electrical fittings removed during repair proce-
dures. These parts are not normally provided with
replacement assemblies.
2. Test repair after problem is corrected.
3. If sprayer does not operate properly, review
repair procedure to verify procedure was done
correctly. If necessary, see Troubleshooting Guide,
page 9, for other possible solutions.
MOVING PARTS HAZARD;
page 4.
4. Install belt guard before operation of sprayer
and replace if damaged. Belt guard reduces risk of
pinching and loss of fingers; see preceding
WARNING.
Grounding
FIRE AND EXPLOSION
HAZARD; page 4.
Ground sprayer with grounding clamp to earth ground
when flushing sprayer. Fig. 1.
Fig. 1
General Repair Information
grounding
clamp
water pipe, steel
sign post, or metal
light pole
06250
SAE O-Ring Installation
1. Unscrew lock nut to touch fitting.
2. Lubricate o-ring
3. Screw in fitting hand tight.
4. Unscrew fitting until oriented properly.
5. Tighten lock nut to indicated torque.
(Make sure washer is seated
properly without pinching o-ring).
309896
7