ATEX SAFETY GUIDE (A)
ATEX directives, for products used in potentially explosive atmospheres are based on the European Committee directive 94/9/EC. This Peltor
products is tested and certified according to ATEX and IECEx directives by Notified Body ID 0470 (Nemko Norway). Manufacturing process is
certified according to ATEX directives by Notified Body ID 0470 (Nemko Norway).
Declaration of conformity:
Peltor declares the ATEX certified products comply with essential requirements and other relevant provisions of directive 94/9/EC.
Relevant Specifications for Ex i, intrinsically safety:
Ex ib IIC T4 II 2 G, Ex I MI Ex ia l
Safety Guide:
1. Make sure that specifications interfaces between this Peltor product and the radio transceiver have been compared according to EN 60079-14
(clause 12.2.5).
2. Only Peltor original approved accessories, like radio cables, are allowed to be used with this Peltor product
3. No connection to this product are allowed inside the potentially explosive atmosphere.
4. Service: use only Peltor authorised service
5. Read carefully the users guide before using this product
6. This product can only be used in temperatures -20°C to + 40°C when used
approved battery types (See below).
Ambient temperature rang is depending on the used cell type. (See below).
Only the following batteries (cell types) are approved for use with this equipment:
Manufacturer:
Duracell
Energizer
The batteries shall not be replaced in an explosive atmosphere
NOTE
Special regulations for safe usage:
The Ex certificate (EC-Type Examination certificate: Nemko 10ATEX 1029X) contains restrictions about electronic data for connected equipment.
Specification of interface Tactical XP:
Maximum allowed input parameters are:
Uimax: 14V
limax: 1,2A
Limax: Negligible
Cimax: 231nF
Pimax: 1,3W
Other line input parameters according to specification of interface document
Tactical XP Intrinsically Safe
Peltor Tactical XP has an audio input for connecting an external radio, and a level dependent function that amplifies soft sounds and dampens
loud noises. The external communication and level dependent functions are independent of each other, which ensures extra good reliability and
better safety. This product has been tested and approved according to:
PPE directive 89/686/EEC and EMC directive 89/336/EEC, which means that it meets the demands for CE labelling
ATEX, see ATEX SAFETY GUIDE (A)
Read these instructions carefully to ensure the best possible benefit from your new Peltor product.
FUNCTIONS
• Tactical XP is equipped with balance, equalizer, adjustable release time, adjustable volume for external input and external input mode.
• The latest settings are stored at shut-off, except high volume on external input
• Automatic shut-off after two hours of no active functions. Two warning signals are emitted every ten seconds for one minute after 1:59 hours
of use, to indicate that the unit will switch off.
• Low battery power is indicated with three warning signals ten hours before the headset will switch off. The interval between the warning
signals will then decrease as the power of the battery weakens.
Always switch off the headset before replacing batteries
Battery type:
MN1500, Procell PC1500
E91, Industrial EN91
Ta: –20°C to +40°C
Ta: –20°C to +40°C