9.9 ADVANCED MENU
This menu allows a more detailed customization of some parameters. To enter, press and hold the "MENU" key for at least 5
seconds. To change the parameters proceed as indicated for the base menu.
WARNING! - after 2 minutes of inactivity the control panel automatically exits the menu.
PARAMETER
Select input device for opening:
0 = disabled
1 = PH1
IAO
1
2 = PH2
3 = S1
4 = S2
Select input device for closing:
0 = disabled
1 = PH1
IAC
2
2 = PH2
3 = S1
4 = S2
5 = PH3/S3
Mode of activation of the opening (IAO > 0):
IOM
3
0 = on commitment
1 = on disengagement after commitment
Mode of activation of the closing (IAC > 0):
ICM
4
0 = on commitment
1 = on disengagement after commitment
Polarity PH1 input:
PH1
5
0 = NC contact
1 = NO contact
Polarity PH2 input:
PH2
6
0 = NC contact
1 = NO contact
Polarity S1 input:
S1
7
0 = NC contact
1 = NO contact
Polarity S2 input:
S2
8
0 = NC contact
1 = NO contact
Polarity PH3 and S3 inputs:
PS3
9
0 = NC contact
1 = NO contact
Led output management mode in opening movement:
0 = output disabled
1 = LED fixed on and OFF at the end of the movement
OLM
10
2 = LED fixed on and ON at the end of the movement
3 = LED flashes and OFF at end of movement
4 = LED flashes and ON at end of movement
6-1622396 - rev. 3 - 21/09/2021
DESCRIPTION
DEFAULT
MIN
MAX
CUSTOM
0
0
4
0
0
5
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
1
0
4
English - 27 / 36