10. RESOLVING PROBLEMS
The anomalies, or error states, are reported by turning on both red and green Leds (if the LED strips are installed) and displaying a
message in the display of the control unit.
In case of alarm/error of the control unit, the LED outputs are managed in fixed mode and not following the settings of the OLM,
CLM and blm parameters.
DISPLAY
DESCRIPTION
eme
Memory error: External memory not mounted or not recognized.
eex
Memory write error: x is a number from 1 to 6. In case of error please contact technical support.
efO
Intervention of impact sensor.
ebS
Thermal intervention to protect the control unit.
eph
Photocells malfunctions.
eth
Thermal intervention to protect the control unit.
fuL
Empty aviable storage space in external memory.
err
Memory error during position display functions or individual transmitter deletion.
11. DECLARATION OF CONFORMITY
Manufacturer: Allmatic srl
Address: Via dell'Artigiano, 1 - 32026 Borgo Valbelluna (BL) Italia
Telephone: +39 0437 751175
E-mail: info@allmatic.com
Web site: www.allmatic.com
We declare under our responsibility that BOOMY operator is conforming to the following standard:
2014/35/EU - Low Voltage Directive
2014/30/EU - Electromagnetic Compatibility Directive
2014/53/UE - Radio Equipment Directive
This product can not work alone and was designed to be fitted into a system made up of various other elements. Hence, it falls within
Article 6, Paragraph 2 of the EC¬Directive 2006/42 (Machines) and following modifications, to which respect we point out the ban
on its putting into service before being found compliant with what is provided by the Directive.
This statement is provided in a shorter form for graphic reasons. The full version is available by contacting the manufacturer.
34 / 36 - English
6-1622396 - rev. 3 - 21/09/2021