PARAMETER
DEAD-MAN MODE:
deA
23
0 = disabled
1 = enabled
Cycle threshold for assistance request. Once the threshold is
reached, the next cycles will be executed with fast flashing (if
SEr
24
Fpr is active).
0 = disabled
Enabling continuous flashing for assistance request (function
performed only with closed automation):
SEf
25
0 = disabled
1 = enabled
Duration of the motor stop ramp, in case of immediate stop due
SFt
26
to alarms or protections. Not considered in case of wired STOP
command.
EnP
27
Time of encoder.
dEF
28
Setting the default values (RESET)
TRS
29
Display single transmitter memory position.
trC
30
Delete single transmitter.
All radio memory erased. Enter to change the parameter and then
trF
31
hold down the «MENU» key, a countdown appears and ends with
the word don.
SId
32
Not in use
1. SELECT INPUT DEVICE FOR OPENING IAO (0 – 4) default = 0
With this parameter you can select which photocell or loop controls the opening. WARNING! It is not possible to select PH3 or S3
for this function as they are reserved for detection of presence near the automation.
Value 0 = function disabled.
Value 1 = PH1 (photocell 1) command the opening.
Value 2 = PH2 (photocell 2) command the opening.
Value 3 = S1 (loop 1) command the opening.
Value 4 = S2 (loop 2) command the opening.
2. SELECT INPUT DEVICE FOR CLOSING IAC (0 – 5) default = 0
With this parameter you can select which photocell or loop controls the closing. WARNING! If PH3 or S3 are selected for this
function they, in addition to being able to control a closure on disengagement, will continue to function as security reversing the
motion in case of intervention during the closing of the bar.
Value 0 = function disabled.
Value 1 = PH1 (photocell 1) command the closing.
Value 2 = PH2 (photocell 2) command the closing.
Value 3 = S1 (loop 1) command the closing.
Value 4 = S2 (loop 2) command the closing.
Value 5 = PH3 and S3 (security photocell and loop near the automation) command the closing after the transit.
6-1622396 - rev. 3 - 21/09/2021
DESCRIPTION
DEFAULT
MIN
MAX
CUSTOM
0
0
1
0
0
100
0
0
1
3
0
20
7
4
80
0
0
0
English - 29 / 36
UM
x1000
cicli
x100ms
ms