4.2. Parameters Menu
Dial '2' from the Main Menu to access to the Parameters Menu.
This menu allows to modify the operative parameters in the MDS CITY/DIRECT
Guard Unit such as times and language.
Parameters Menu: 1. Minimum Time
P 1 2 3 4 5 6 7
a Tm c
L
It sets the minimum time, in seconds, during which is not possible
to interrupt the communication. Valid values are from 10 to 60
seconds.
For installations with MDS-CITY or MDS-DIRECT panels, the
time programmed in these panels will be prioritary.
Parameters Menu: 2. Conversation Time
P 1 2 3 4 5 6 7
a Tm c
L
Sets the maximum conversation time between 10 and 250
seconds.
For installations with MDS-CITY or MDS-DIRECT panels, the
time programmed in these panels will be prioritary.
Parameters Time: 6. Language
P 1 2 3 4 5 6 7
a Tm c
L
Choose 1, 2 or 3 to set the language used to show the messages
in the display: 1 spanish, 2 english, 3 french.
4.3. Decoders Menu
Decoders Menu will be shown by pressing '3' from the Main Menu.
By means of this menu, we will be able to program the numbers for all the
outputs in the decoders.
Decoders Menu: 1. Individual Programming
Allows to program the outputs of a single decoder, one by one.
D 1 2 3 4
e In Se Co Tel
Once the option has been chosen, the steps to follow are:
1. Press the programming button in the decoder to be
2. Dial a new number (to change it) and press 'B'.
3. Repeat the previous step for every other output in the
In case of audio decoders, the number to be dialed is a 4 digits number
while 3 digits are used for panels.
Pag 28
programmed. Read the manual provided with decoder.
The top-line of the display will show the type of decoder
selected (ISO, AUDIO-4, AUDIO-8, PANEL-4) and the bottom-
line will show the telephone or panel number programmed in
its first output.
decoder.