Red and Yellow LEDs are
blinking fast
Red and Yellow LEDs are
blinking while switching
Solid state contact does
not follow status Red LED
Yellow LED is lit while
probe is not covered
Fully Synthetic Process Connection (Enclosure
Version)
Symptom
Green LED off
Green LED off, with proper
supply
Green LED on and Yellow
LED on while not
responding to product
and/or adjustment
Hysteresis region too
great
A5E32146158
Proper power not applied
to device.
Power range must equal
12 to 33 V DC at all times
(10 to 30 V DC for IS
versions)
Proper power not applied
to device.
Power range must equal
12 to 33 V DC at all times
(10 to 30 V DC for IS
versions)
Defective component in
device. Probable cause:
wrong wiring in this
circuit.
May indicate significant
product buildup.
Cause
Proper power not
applied to device
Power range must equal
12 to 33 V DC at all times
(10 to 30 V DC for IS
versions)
Defective component in
device.
Connector came loose
Proper power not
applied to device.
Power range must equal
12 to 33 V DC at all times
(10 to 30 V DC for IS
versions)
Proper power not
applied to device
Power range must equal
12 to 33 V DC at all times
(10 to 30 V DC for IS
versions)
Pointek CLS100 – QUICK START MANUAL
Check power source
Minimum 12 V DC on the terminals
when the signal current is 20 mA
(minimum 10 V DC for IS versions)
Check power source
Minimum 12 V DC on the terminals
when the signal current is 20 mA
(minimum 10 V DC for IS versions)
Contact distributor
Rotate sensitivity potentiometer
further CCW (counter clockwise)
Check sensor tip
Action
Check power source
Minimum 12 V DC on the terminals
when the signal current is 20 mA
(minimum 10 V DC for IS versions)
Contact distributor
Refasten connector
Check power source
Minimum 12 V DC on the terminals
when the signal current is 20 mA
(minimum 10 V DC for IS versions)
Check power source
Minimum 12 V DC on the terminals
when the signal current is 20 mA
(minimum 10 V DC for IS versions)