Figure 10 – Installing Cable End Into Holder
5. Replace drum back and retighten the screw to capture
the end of the cable between the drum halves.
6. Feed cable into drum.
Chart 1 Troubleshooting
PROBLEM
Cable kinking or breaking.
POSSIBLE REASONS
Cable is being forced.
Cable used in incorrect pipe diameter.
Motor switched to reverse.
Cable exposed to acid.
Cable worn out or damaged.
Cable not properly supported.
Ridge Tool Company
Power Spin™ Drain Cleaner
SOLUTION
Do Not Force Cable! Let the auger do the work.
Do not use in lines over 1
1
/
Use reverse only if cable gets caught in pipe or to
retract cable.
Clean cables routinely.
If cable is worn or damaged, replace it.
Support cable properly, see instructions.
" .
2
5