Chamberlain LiftMaster 379E Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
ERASE/RESET
• To erase users:
NOTE: Erasing a user will erase ALL stored fingerprints. User
does NOT need to reprogram to opener.
1. Open cover and wait until Ready
LED is lit.
2. Enrolled user must slowly and firmly
swipe fingerprint.
3. Press and hold the Enroll button for
at least 6 seconds. The Pass LED and
Fail LED will flash for 15 seconds.
During this time the Resend button is
active. After 15 seconds the Enroll and
Ready LEDs will light indicating
fingerprints are erased. The unit will
return to Enroll mode.
• To return unit to Factory Reset state:
NOTE: Factory reset state will erase ALL stored fingerprints.
This method should be used ONLY when an enrolled user is
not available as it requires user to reprogram unit to opener.
1. Open cover and wait until Ready
LED is lit.
2. Press and hold the Enroll button
until all LEDs turn off. Release
button.
3. Again press and hold the Enroll
button until the Ready and Enroll
LEDs are lit and not flashing.
TROUBLESHOOTING
• If no known enrolled users are available:
- The memory must be erased using the Factory Reset
process.
• If the unit does not recognize a swiped fingerprint:
- Ensure that the Ready LED is lit before you swipe.
- Ensure that fingerprint is swiped correctly (See Tips for
Success).
- Ensure that fingerprint is enrolled.
- Ensure that sufficient pressure is being applied to sensor
strip (do not press too hard).
- Ensure that the sensor and finger are not wet.
1
ENROLL
SEND
ENROLL
PASS
FAIL
READY
RETRY
2
3
1
ENROLL
SEND
ENROLL
PASS
FAIL
READY
RETRY
2
3
• If finger is enrolled but unit will not program to opener:
- Ensure that the opener has an orangee "learn" button. If
opener does not have an orange "learn" button it is not
compatible with the unit.
• If the unit is in Enroll mode at power up:
- Complete enrollment process for initial user.
- The initial enroll process failed (signalled by a lit Enroll
LED and Fail LED) and must be repeated.
• If enrolling new user and all LEDs flash and unit returns
to Ready mode:
- The memory is full. In order to add new user, the memory
needs to be erased. Refer to Erase User or Factory Reset.
• If the unit does not wake:
- A button may be stuck. Press Enroll and Resend buttons
to ensure free movement.
- The batteries may need to be replaced.
• If the Fail LED flashes during use:
- The batteries need to be replaced.
NOTE: If sensor is dirty, user should wipe sensor with a clean
finger. It is recommended that the sensor be periodically
cleaned with a lint-free cloth dampened with alcohol.
THE BATTERY
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor
The batteries should produce power
for at least one year.
Replace when the Fail LED flashes
during use. The unit
requires 4 AAA batteries.
Dispose of old batteries properly.
1. Slide cover completely off.
2. Unscrew the two screws and
remove the battery cover.
3. Replace the batteries. Screw the
battery cover back on.
4. Slide cover back into place.
Sparepart:
Cover.................................................................................41A6481
D e c l a r a t i o n o f C o n f o r m i t y
The
undersigned,
hereby
conforms to the Directives and Standards stated.
Model:
EN 301 489-3, EN 300 220-3
2004/108/EC
1999/5/EC
Chamberlain GmbH
Alfred-Nobel-Strasse 4
D - 66793 Saarwellingen
June, 2008
Cover
Battery
Cover
Screws
SEND
PASS
READY
declare
that
the
equipment
specified
379E
Barbara P. Kelkhoff
Manager, Reg. Affairs
ENROLL
ENROLL
FAIL
RETRY

Publicidad

Tabla de contenido
loading

Tabla de contenido