Menu; Special Accessory; Perform Test; Connecting Bat - Bosch BAT 125 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

en
6 | BAT 125 | Perform Test
3.6

Menu

1. Press Q to access the Menu.
2. Use the  or  to highlight the line you want to edit.
3. Press
to edit the line or save your changes.
E
4. Use  or  to select the function to use or edit.
5. Press
to move to the next location.
E
6. Press Q to return to the Menu.
Option
Description

Perform Test

Begin the Battery and System Test pro-
cedure.
Voltmeter
Start the test battery voltage.
View / Print
Display the previous test result. Press
the
Counter
Clear or display battery and system test
by results.
Settings
Customize tool options to fit your needs.
Language
Select a language for the tester.
Default: English
Set Address
Create a header for your printed test re-
sults with your business location infor-
mation.
Set Time
Select 24-hour or AM/PM and set the
time.
Default: AM/PM
Set Date
Select the date format and date.
Default: MM/DD/YYYY
Contrast
Adjust the contrast setting of the tes-
ter display.
Default: 23
Temperature Units Select the temperature units Degrees °F
or Degrees °C.
Default: Degrees F
Amp Clamp
Prompt for Amp Clamp availability.
Version Info
Lists the software version, software ver-
sion date, and serial number.
Update
Update the tester's internal operating
software.
3.7

Special accessory

Designation
Item number
Current probe
1 681 354 034
|
1 689 989 125
2013-09-09
button to print the results.
4.
Perform Test
4.1
Test Preparations
!
If performing the battery test in a vehicle, ensure
that
$
all additional loads are deactivated,
$
the key is not in the ignition,
$
all doors are closed,
$
measuring is not carried out by or with steel
bolts.
i
Before connecting the tester, clean the battery posts
or side terminals with a wire brush and a mixture of
baking soda and water.
4.2

Connecting BAT 125

!
For a proper connection, rock the clamps back and
forth. The tester requires that both sides of each
clamp be firmly connected before testing. A poor
connection will produce a
WIGGLE CLAMPS
message. If the message appears,
clean the terminals and reconnect the clamps.
i
The preferred test position is at the battery termi-
nals. If the battery is not accessible, you may test at
the jumper post; however, the available power mea-
surement may be lower than the actual value.
4.2.1

Directly on battery posts (TOP POST)

1. Connect the red clamp directly to the positive post
(+).
2. Connect the black clamp directly to the negative
post (–).
4.2.2
On side battery posts via lead post adapter
(SIDE POST)
!
Test results will be inaccurate, if there is no
$
lead post adapter or
$
worn or dirty lead post adapters are used.
!
Tighten the lead post adapter with an adjustable
wrench by a max. of ¼ turn.
1. Connect the red clamp via the lead post adapter
(available from specialist stores) on the side positive
post (+).
2. Connect the black clamp via the lead post adapter
(available from specialist stores) on the side nega-
tive post (–).
CHECK CONNECTION
or
Robert Bosch GmbH

Publicidad

Tabla de contenido
loading