Disassembly And Disposal; Maintenance; Technical Data - SICK WLD26 Instrucciones De Operación

Ocultar thumbs Ver también para WLD26:
Tabla de contenido

Publicidad

9

DISASSEMBLY AND DISPOSAL

9
Disassembly and disposal
10

Maintenance

11

Technical data

Sensing range (with reflector PL80A)
Light spot diameter/distance
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
10
LED indicator/fault pattern
Yellow LED flashes
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Cause
Distance between sensor
and reflector is too large /
light beam is not completely
aligned to the reflector /
reflector is not suitable / Front
screen and/or reflector is con‐
taminated.
WLD26P
0.25 ... 14 m
Ø 16 mm / 1 m
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
≤ 500 μs
3)
1000 Hz
4)
Measures
Check sensing range / check
alignment / SICK reflector is
recommended / Cleaning of
the optical surfaces (sensor
and reflector).
8020356.19RH / 15.01.2021 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido