reclose the fuse cover.
The fuse FU7 must NOT be fitted if the machine is provided with gel batteries.
To replace the fuses inside the electrical box, proceed as follows:
►
stop the machine, turn the main switch (fig. 8, ref. 13) to the "0" position (off) to disable all
the machine's functions;
►
remove the bonnet (fig. 2, ref. 4);
►
remove the cover of the electrical box (fig. 21, ref. 1);
►
with the tweezers supplied with the machine take out the blown fuses and replace them
with new ones of the same amperage;
►
re-close the cover of the electrical box;
►
refit the bonnet.
FUSE
DESCRIPTION
FU1
General fuse of power
FU4
Suction motor fuse
FU5
Control protection fuse
Fuse chart: for a chart of the fuses see the Catalogue of Spare Parts.
Never fit a fuse with a higher Amp value than the intended one.
If a fuse keeps burning, it is necessary to identify and repair the damages present in the wiring,
boards (if fitted) or motors: have the machine checked by trained technical staff.
Periodic maintenance
Daily maintenance
Every day at the end of work perform the following operations:
►
stop the machine, turn the main switch (fig. 8, ref. 13) to the "0" position (off) to disable all
the machine's functions;
►
engage the parking brake by means of the pedal (fig. 8, ref. 12);
►
empty the recovery tank and clean it, if necessary;
►
clean the squeegee blades, checking that they are not excessively worn; replace them, if
necessary;
►
make sure that the squeegee suction hole is not clogged, freeing it from any encrusted dirt;
►
recharge the batteries according to the procedure described above.
Weekly maintenance
►
Clean the floating rod of the recovery tank and check that it works correctly;
►
clean the suction air filter and check that it is not damaged (replace it, if necessary);
►
clean the basket strainer located on the front opening of the solution tank (fig. 9, ref. 7) and
make sure it is intact (replace if necessary);
►
clean the suction tube;
►
clean the recovery tank and the solution tank;
►
check the level of the electrolyte in the batteries and top up with distilled water, if necessary.
►
clean the water/detergent tank filter (fig. 22, ref. 1).
Six-monthly maintenance
►
Have the electric system, calibrations checked by qualified staff;
►
VERSION R, HEAD WITH ROLLERS: tension the belts according to the directions in the
specifications.
WARNING
FUSE
FU6
FU7
FU8
WARNING
TROUBLESHOOTING
GB
DESCRIPTION
Brush electronic control switch
Switch for gel batteries
Solenoid valve control switch
29