Battery Requirements; Battery Installation - Generac 0060550 Manual De Instrucciones

Ocultar thumbs Ver también para 0060550:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Battery Requirements

Group 26R, 12V, 540CCA (Minimum CCA)

Battery Installation

WARNING
WARNING
Fill the battery with the proper electrolyte fluid if
necessary and have the battery fully charged before
installing it.
Before installing and connecting the battery, complete the
following steps:
Verify that the generator has been turned OFF.
1.
Turn off utility power supply to the transfer switch.
2.
Remove the 7.5A fuse from the generator control
3.
panel.
See
Figure
6-2. Battery cables were factory connected
at the generator. Connect cables to battery posts as
follows:
WARNING
Explosion. Batteries emit explosive gases.
Always connect positive battery cable first to
avoid spark. Failure to do so could result in
death or serious injury.
Connect the red battery cable (from starter
4.
contactor) to the battery post indicated by a
positive, POS or (+).
Connect the black battery cable (from frame
5.
ground) to the battery post indicated by a negative,
NEG or (-).
Install the red battery post cover (included).
6.
NOTE: Dielectric grease should be used on battery
posts to aid in the prevention of corrosion.
NOTE: Damage will result if battery connections are
made in reverse.
Owner's Manual for 60 Hz Synergy Generator™
(000137a)
A. Negative (-) Black lead from frame
B. Positive (+) Red lead from starter contactor
Figure 6-2. Battery Cable Connections
(000138a)
NOTE: In areas where temperatures fall below 32 °F (0
°C), it is recommended that a pad type battery heater be
installed to aid in cold climate starting. This is available
as a cold weather kit through an authorized service
dealer.
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death or serious injury.
Explosion. Do not dispose of batteries in a fire.
Batteries are explosive. Electrolyte solution can cause
burns and blindness. If electrolyte contacts skin or eyes,
flush with water and seek immediate medical attention.
(000133)
Electrical Connections
B
A
+
-
000621
WARNING
WARNING
(000228)
(000162)
25

Publicidad

Tabla de contenido
loading

Tabla de contenido