SATA SATAminijet 3000 B HVLP Instrucciones De Servicio página 75

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
Operating instructions SATAminijet 3000 B HVLP / BT HVLP
Preface
Prior to putting the unit/paint spray gun into operation, read the operating instructions
completely and thoroughly. The stipulations contained therein are to be respected in any
case. After that, the operating instructions are to be stored in a safe place, accessible for
every user of the equipment. The unit/paint spray gun may only be put into operation by
persons familiar with its use (professionals). Inappropriate use of the unit/paint spray gun,
modification of any kind or combination with inappropriate other parts may cause material
damage, serious hazard to the user's, other person's or animal's health or even death.
SATA shall not take any responsibility for such damages (e.g. failure to respect the stipu-
lations laid out in the operating instructions). The applicable safety, workplace and worker
health protection regulations of the respective country or area/district in which the system/
the paint spray gun is used are to be respected in any case (e.g. the German Rules for the
Prevention of Accidents BGR 500 issued by the Central Office of the Professional Trade
Associations, etc.)
To be noted
Never point paint spray guns at yourself, at other persons or animals. Solvents and thin-
ners can cause burns. Only the respective quantities of solvents and paints required for
work progress may be present in the direct surroundings of the unit (after work, solvents
and paints are to be returned to their assigned storage rooms). Prior to any repair work
the unit must be disconnected from the air supply. Prior to putting the unit into operation,
especially after each cleaning and each repair work, check all screws and nuts for tight fit,
as well as the sealing performance of the spray guns and hoses. Defective components
must be replaced or repaired accordingly. To obtain best possible coating results, and for
maximum safety, only use original spare parts. No sources of ignition (e.g. open flames,
burning cigarettes, lamps without ex-protection etc.) may be present during painting, as
easily flammable mixture are generated during the painting process. Occupational safety
regulations must be applied when painting (respiratory protection, etc.). Appropriate ear
protection muffs are required, as a sound level of 90 dB(A) is exceeded when coating with
higher pressure levels. No vibration is transmitted to the upper parts of the operator's body
during use of the paint spray gun. Recoil forces are negligible.
The use of this product in explosion hazard areas Zone 0 is prohibited.
SATA, SATAminijet, the SATA Logo and/or other SATA products referenced herein are either
registered trademarks or trademarks of SATA GmbH & Co. KG in the U.S. and/or other
countries. The names of companies and products mentioned herein may be the trademarks
of their respective owners.
1. Features and technical Data
• Paint spray gun with nozzle 0.8 HVLP
• Air consumption at 2 bar: approx. 115 NL/min
• Recommended spray gun inlet pressure 2 bar
• Max. operating pressure: 2 bar
• Max. operating temperature material: 80° C
• PVC gravity flow cup 125 ccm*
• Angle connection DN 4**
• Tool kit
* only for SATAminijet 3000 B HVLP
** only for SATAminijet 3000 BT HVLP
All manuals and user guides at all-guides.com
IX.1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sataminijet 3000 b t hvlp

Tabla de contenido