Program Mode; Front / Remote Selection - Agilent Technologies Turbo-V 250 Manual De Instrucciones

Tabla de contenido

Publicidad

17
Technical Information
Use

Program Mode

The following instructions are applicable to Turbo-V 250 Controller model 969-
NOTE
9504 only when the optional "hand held terminal" is installed.

FRONT / REMOTE Selection

S
S
The Soft Start mode may be deselected/selected only when the pump is
NOTE
stopped.
218/240
Press CYCLE NUMBER and PUMP CURRENT push-buttons
together for at least 2 seconds and the processor enters in a
routine where it is possible to program the controller.
In this routine, the CYCLE push-button is used for
choosing/changing the value or condition; the PUMP CURRENT
push-button is used to enter and confirm the value. At any time it
is possible to exit this routine by pressing the CYCLE and PUMP
CURRENT push-buttons at the same time for at least 2 seconds.
The display shows:
O
F
T
S
E
L
E
C
T
where: XXX = YES or NO.
If YES is selected, the Soft Start mode allows the pump to rump-
up the Normal speed within ten steps. When NO is selected, the
Soft Start mode is deselected and the rump-up of the pump will
be done within 180 seconds.
The controller is factory set to YES.
Turbo-V 250 Controller User Manual / 87-900-856-01 (E)
T
A
R
T
I
O
N
:
M
O
D
E
X
X
X