Before Use; During Use; After Use - Holmatro Varipump M304 Manual

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 111
6.2

Before use

6.2.1
General
Use the pump only for tools that require an hydraulic oil volume that is less than the maximum available
oil volume.
Position the pump on a solid level base.
Check the hydraulic oil level.
Check the fuel level of the petrol engine. Refer to section 4.3.2.
Connect the hydraulic hoses to the tool and the pump. Refer to section 5.2.
DANGER
The exhaust gases contain carbon monoxide that can cause unconsciousness or death:
Keep at a distance.
Never use a pump in an enclosed space and always make sure there is enough
ventilation.
Start the pump. Refer to chapter 5.4.
Caution
Allow a petrol motor to reach its operating temperature before using the pump.
Operate the pressure relief valve. Refer to the manual supplied with the valve.
The system is now ready for use.
6.3

During use

The pump is provided with a control valve. The pump develops oil pressure as soon as the motor runs.
Any pressure developed is released to the tank if the valve is in its "release" position. Only if the pump is
in its "operation" position the oil flows to the tool and pressure develops.
6.3.1
Change a tool
Disconnect the hoses from the tool in use. Refer to chapter 5.3.
Connect the hoses to the other tool. Refer to chapter 5.2.
6.4

After use

6.4.1
Shut down and disconnect
Stop the pump. Refer to chapter 5.5.
Disconnect the hydraulic hose(s) from the tool and the pump. Refer to chapter 5.3.
Electric motor: disconnect the power cord.
6.4.2
Inspection
Check the pump for completeness, oil leaks and damage. Do not use the pump if it leaks or is
damaged and contact the Holmatro dealer.
Check the level of the hydraulic oil in the tank, and add oil if necessary.
Varipumps
All manuals and user guides at all-guides.com
916.219.123_002
EN
49

Publicidad

Tabla de contenido
loading

Tabla de contenido