8

Technical Data

Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once,
full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1014-2R or BTL-P-1012-4R:
Resolution
Hysteresis
Repeatability
(resolution + hysteresis)
System resolution is determined
by the processor or external con-
troller.
Recommended sampling rate:
Nominal length
< 1000 mm
0.5 to 2 kHz
< 2000 mm
0.5 to 1 kHz
> 2000 mm
0.5 kHz
Non-linearity:
Nom. length < 500 mm > 500 mm
±100 µm ±0.02 % FS
Temperature coefficient
(6 µm + 5 ppm * nominal length)/K
Shock loading
100 g/6 ms
per EN 60068-2-27
1
Continuous shock
100 g/2 ms
per EN 60068-2-29
1
Vibration
12 g, 10 bis 2000 Hz
per EN 60068-2-6
1
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a
hydraulic cylinder
1
Individual specifications as per
Balluff factory standard
8.1
Dimensions, weights,
ambient conditions
Nominal length
< 5500 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions
Weight
ca. 2 kg/m
Housing/Flange
Stainless steel
1. 4404
Pressure tube
Stainless steel
1.4571
Diameter
10.2 mm
wall thickness
2 mm
e-modulus
ca. 200 kN/mm
Mounting threads
M18×1.5 or 3/4"-16UNF
Operating temp.
–40 °C to +85 °C
Humidity
< 90 %, non-dewing
Protection rating per IEC 60529
with connector attached:
cable version
IP 68
(type tested at 5 bar / 48 h)
IP69/K with connected cable guard
system
< 2 µm
8.2

Supply voltage (external)

< 4 µm
Regulated supply voltage
< 6 µm
BTL5-_1...
Ripple
Current draw
Inrush
Polarity reversal protection built-in
f
Overvoltage protection
Standard
Transzorb diodes
Electric strength
GND to housing 500 V DC
8.3

Control signals

INIT pulse
Level
driver Length
8.4

Connection to processor

BTL5-...-FA05
with connecting cable,
axial arrangement, 5 m long
BTL5-...-F05
with connecting cable,
radial arrangement, 5 m long
Teflon cable
2004/108/EC (EMC Directive)
and the EMC Law. Testing in our
2
EMC Laboratory, which is accred-
ited by DATech for Testing Elec-
tromagnetic Compatibility, has
confirmed that Balluff products
meet the EMC requirements of
the following Generic Standards:
EN 61000-6-1 (noise immunity)
EN 61000-6-2 (noise immunity)
EN 61000-6-3 (emission)
EN 61000-6-4 (emission)
and the following product standard:
EN 61326-2-3
20 to 28 V DC
< 0.5 V
pp
< 90 mA (at 1 kHz)
< 3 A/0.5 ms
+5 V RS 485/422
1 µs (max. 3 µs)
-40 °C to +200 °C
The CE Mark verifies
that our products meet
the requirements of
EU Directive
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
Emission tests:
RF Emission
EN 55016-2-3 (industrial and
residential area)
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4