Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Outputs - Balluff BTL5-A/C/E/G1 Serie Manual Del Usaurio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-A/C/E/G1 _-M_ _ _ _-HB/WB-FA_ _/F_ _-C
Micropulse Linear Transducer - Rod Style
8

Technical Data

Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once,
full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1014-2R or BTL-P-1012-4R:
Repeatability
Voltage
0.3 mV
Current
0.6 µA
Minimum
5 µm
Sampling rate:
Nom. length
f
Standard
< 2000 mm
1 kHz
> 2000 mm
0.5 kHz
Non-linearity
Nom. length < 500 mm > 500 mm
in µm
±100
±0.02 % FS
Temperature coefficient
Voltage output:
[150 µV/K + (5 ppm/K * P * V/NL)] * ∆T
Current output:
[0.6 µA/K + (10 ppm/K * P * I/NL)] * ∆T
V
= output voltage range in [V]
I
= output current range in [mA]
NL = nominal length in [mm]
∆T = temperature coefficient in [K]
P
= magnet position in [mm]
Shock loading
100 g/6 ms
1
per EN 60068-2-27
Continuous shock
100 g/2 ms
1
per EN 60068-2-29
Vibration
12 g, 10 bis 2000 Hz
1
per EN 60068-2-6
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a hydraulic cylinder
1
Individual specifications as per Balluff
factory standard
8.1
Dimensions, weights,
ambient conditions
Nominal length
< 5500 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions
Weight
ca. 2 kg/m
Housing/Flange
Stainless steel
1. 4404
Pressure tube
Stainless steel
1.4571
Diameter
10.2 mm
Wall thickness
2 mm
e-modulus
ca. 200 kN/mm
Mounting threads
M18×1.5 or 3/4"-16UNF
Operating temp.
–40 °C to +85 °C
Humidity
< 90 %, non-dewing
Protection rating per IEC 60529
with connector attached:
cable version
IP 68
(type tested at 5 bar / 48 h)
IP69/K with connected cable guard
system
8.2

Supply voltage (external)

Regulated supply voltage
BTL5-_1...
DC 20 to 28 V
Ripple
< 0.5 V
Current draw
< 150 mA
Inrush
< 3 A/0.5 ms
Polarity reversal protection built-in
Overvoltage protection
Transzorb diodes
Electric strength
GND to housing 500 V DC
8.3

Outputs

BTL5-A11...
Output voltage
Load current
Ripple
BTL5-G11...
Output voltage
–10...10/10... –10 V
Load current
Ripple
BTL5-C1_...
Output current 0...20/20...0 mA
Load resistance
BTL5-E1_...
Output current 4...20/20...4 mA
Load resistance
The CE Mark verifies
that our products meet
the requirements of
EU Directive
2004/108/EC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Elec-
tromagnetic Compatibility, has
confirmed that Balluff products
2
meet the EMC requirements of
the following Generic Standards:
EN 61000-6-1 (noise immunity)
EN 61000-6-2 (noise immunity)
EN 61000-6-3 (emission)
EN 61000-6-4 (emission)
and the following product standard:
EN 61326-2-3
8.4
BTL5-...-FA05
with connecting cable,
axial arrangement, 5 m long
pp
BTL5-...-F05
with connecting cable,
radial arrangement, 5 m long
Teflon cable
0...10/10...0 V
< 5 mA
< 5 mV
< 5 mA
< 5 mV
< 500 Ohm
< 500 Ohm
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
Emission tests:
RF Emission
EN 55016-2-3 (industrial and
residential area)
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Fast transients (Burst)
EN 61000-4-4
Surge
EN 61000-4-5
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8

Connection to processor

-40 °C to +200 °C
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 4
english
9

Publicidad

Tabla de contenido
loading

Tabla de contenido