Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Output Signals - Balluff BTL6-E500-M E2 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL6-E500-M_ _ _ _-E2/E28-KA_ _/KE_ _/LA_ _
Micropulse Transducer - Rod Style
8

Technical Data

Typical values at DC 24 V, room temperature and BTL6-E500-... with nominal length 500 mm and KA02. Ready to
use, full accuracy reached after warm-up phase. With magnet BTL-P-1013-4R, BTL-P-1014-2R, BTL-P-1012-4R or
BTL-P-0814-GR-PAF:
Resolution
typical
± 7 µA,
with input filter 27 KHz
Sampling rate
nom. length
< 1300 mm
> 1300 mm
nom. length
Non-linearity:
< 500 mm < ±200 µm
nom. length
nom. length
> 500 mm < ±0.04 % FS
typ.±0.02 %FS
Temperature
coefficient
typ. 25 µm/K
8.1
Dimensions, weights,
ambient conditions
➥ ➥ ➥ ➥ ➥ page 4
Dimensions
Weight
approx. 2.0 kg/m
Housing
Stainless steel 4404
Pressure tube Stainless steel 4571
BTL6...E2
nom. length
< 1500 mm < 1016 mm
Diameter
10.2 mm
Wall thickness 2 mm
E-Moduls
approx. 200 kN/mm²
Support ring
PTFE
O-Ring
NBR
-40 °C to 85 °C
Operating temp.
Storage temp. max. 90 °C
The CE Mark verifies
that our products meet
the requirements of
EC Directive
89/336/EEC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet
the EMC requirements of the fol-
lowing Generic Standards:
EN 61000-6-4 (emission)
EN 61000-6-2 (noise immunity)
8
english
Humidity < 90 %, non-dewing
Protection rating IEC 60529
when closed up
Shock loading
per IEC 60068-2-27
1 kHz
Continuous shock 50 g/2 ms
0.5 kHz
per IEC 60068-2-29
Vibration 12 g, 10 to 2000 Hz
per IEC 60068-2-6
(take care to avoid natural
resonance of protective )
Pressure
BTL6...E2
BTL6...E28
when installed in a hydraulic
cylinder
1
Individual specifications as per Balluff
factory standard
8.2

Supply voltage (external)

Regulated supply
voltage
BTL6...E28
Ripple
Current draw typical 2 W
8 mm
Inrush typical
0.9 mm
(Sampling rate 1 KHz)
Overvoltage
Polarity reversal
protection
Emission tests:
RF Emission
EN 55011
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Fast transients (Burst)
EN 61000-4-4
Surge
EN 61000-4-5
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8
IP 67
100 g/6 ms
1
1
1
up to 350 bar
up to 250 bar
DC 10 ... 30 V
< 0.2 V
ss
< 80 mA
at 24 V DC
36 V
max. 40 V
Group 1, Class A+B
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 4
8.3

Output signals

Position signal
BTL6-E
4 - 20 mA
Error signal
BTL6-E
< 4 mA, typ. 3.6 mA
8.4

Overvoltage protection

Dielectric strength with
respect to housing
BTL6-...E2-
Compatibility tests (EMC Directi-
ve):
ISO 14982
Agricultural and Forestry
Machinery
ISO 13766
Earthmoving Machinery
ISO 7637-1/2/3
Highway Vehicles
EN 12895
Lift Trucks
EN 50121-3-2
Rail applications
ISO 11452-5 Electromagnetic
field HF, 200 V/m
Restrictions:
External protection measures must
be taken:
EN 150121-3-2:
(Burst 2kV per EN 61000-4-4):
ISO 7637-2 Pulse 5a
External buffering measures must
be taken:
Fluctuations and interruptions in
the supply
(EN 50155)
500 V DC

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl6-e500-m e28-ka serie

Tabla de contenido