Technical Data; Accuracy; Ambient Conditions; Supply Voltage (External) - Balluff BTL7-A/C/E/G5 Serie Manual Del Usuario

Ocultar thumbs Ver también para BTL7-A/C/E/G5 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
BTL7-A/C/E/G5_ _-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Transducer - Rod Style
10

Technical data

10.1

Accuracy

The specifications are typical values at DC 24 V and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S or
BTL-P-1012-4R magnet or with the BTL2-S-6216-8P-Ex,
BTL2-S-5113-4K-Ex, BTL2-S-4414-4Z-Ex or
BTL2-S-4414-4Z01-Ex float.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply. Special versions are indicated by the
suffix -SA on the part label.
Repeat accuracy
Typical
Sampling rate
Dependent on the nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length
> 500 to ≤ 5500 mm
Nominal length > 5500 mm
Temperature coefficient
1)
Max. detectable velocity
10.2

Ambient conditions

Operating temperature
Storage temperature
Humidity
Rod pressure rating (when installed
in hydraulic cylinders)
Shock rating
Continuous shock
per EN 60068-2-27
2), 3)
Vibration
per EN 60068-2-6
2), 3)
Degree of protection per IEC 60529
22
english
10.3
Voltage, stabilized:
BTL7-_5_ _-...
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
10.4
±10 µm
BTL7-A... Output voltage
250 µs...5.7 ms
BTL7-C... Output current
500 µs
BTL7-E... Output current
±50 µm
BTL7-G... Output voltage
±0.01% FS
±0.02% FS
Short-circuit resistance
≤ 30 ppm/K
10 m/s
10.5
Programming inputs La, Lb:
–40°C...+80°C
BTL7-_5_ _-...
–40°C...+90°C
Overvoltage protection
< 90%, non-
condensing
≤ 350 bar
1) Nominal length = 500 mm, magnet in the middle of the measuring range
2) Individual specifications as per Balluff factory standard
100 g/6 ms
3) Resonant frequencies excluded
100 g/2 ms
4) A prerequisite is that no current can flow between GND and 0 V in the
12 g, 10...2000 Hz
IP68
2)
Ignition protection "d"
Flameproof enclosure

Supply voltage (external)

10...30 V DC
≤ 0.5 V
< 120 mA
≤ 500 mA
4)
Up to 36 V
Up to 36 V
500 V AC

Output

Load current
Load resistance
Load resistance
Load current

Input

event of polarity reversal.
Ensure power is limited to 4 W!
ss
0...10 V and 10...0 V
≤ 5 mA
0...20 mA/20...0 mA
≤ 500 Ω
4...20 mA/20...4 mA
≤ 500 Ω
10...10 V and 10...
10 V
≤ 5 mA
Signal cable to 36 V
Signal cable to GND
High-active
10...30 V DC
up to 36 V

Publicidad

Tabla de contenido
loading