Before you begin

Tools and parts needed

Phillips Head Screwdriver
Pencil
Drill with ¼" (6 mm) bit
Jigsaw
Tape Measure
Note: Additional materials may be necessary for
installation in solid surface countertops. Contact the
countertop manufacturer.

Parts included

Cabinet Requirements

The distance from the top of the cooktop to the bottom
of cabinets above can be reduced to 24" when the
bottom of the wood or metal cabinet is protected by not
less than ¼" (6.35 mm)-thick flame-retardant millboard
covered with not less than No. 28 MSG sheet metal,
0.015 inch (0.4 mm) stainless steel, 0.024 inch (0.6 mm)
aluminium or copper.
Notes
Care must be taken that the necessary space is
allowed for in the lower cabinet under the drain
valve of the appliance.
Don't install VK 230 and VF 230 directly next to
each other!
In case of suspended cabinets a ventilation hood
must be installed above VK 230.

Countertop Requirements

9
WARNING
To reduce the risk of ignition of surrounding
combustible materials, install at least 2" (51 mm)
from both sidewalls and the rear wall.
The countertop must be level and horizontal. The
stability of the countertop must be maintained after the
cut-out has been made.