Gas and Electric Supply Zones
30" Range Width
30" Range Width
30" Range Width
GAS & ELECTRICAL
GAS & ELECTRICAL
GAS & ELECTRICAL
4⅜"
SUPPLY ZONE
SUPPLY ZONE
SUPPLY ZONE
(111)
5¾"
5¾"
5¾"
(146)
(146)
(146)
inches (mm)
Figure 4: Gas & Electrical Supply Locations
NOTICE:
— If not already present, install gas shut-off valve in
an easily accessible location.
— Make sure all users know where and how to shut
off the gas supply to the range.
— Any opening in the wall behind the appliance and
any opening in the floor under the appliance must
be sealed.
The range must be connected only to the type of gas
for which it is certified. If the range is to be connected to
propane gas, ensure that the propane gas supply tank is
equipped with its own high pressure regulator in addition to
the pressure regulator supplied with the range (see "STEP
5: Gas Requirements and Hookup").
NOTE: The range is designed for flush installation to the
back wall. For a successful installation, it may be
necessary to reposition the gas supply line and electrical
cord as the range is pushed back to its final position.
--
SUGGESTION: This may be accomplished by carefully
pulling on a rope or twine looped around the gas or
electrical supply line as the range is pushed back into
its final installed position.
Installation Instructions
2" (51) max.
2" (51) max.
2" (51) max.
protrusion from wall
protrusion from wall
protrusion from wall
for gas and electrical
for gas and electrical
for gas and electrical
supply.
supply.
supply.
"
"
"
18
18
18
7
7
7
/
/
/
16
16
16
5
13
/
16
(468)
(148)
Electrical Supply
Circuit Breaker (A)
Volts (V)
Frequency (Hz)
Plug Type
Power Cord Length
WARNING
This appliance is equipped with a three-prong grounding
plug for protection against shock hazard and should be
plugged directly into a properly grounded receptacle. DO
"
NOT cut or remove the grounding prong from this plug.
DO NOT ALTER THIS PLUG.
The cord supplied with the gas ranges
require a NEMA 5-15 receptacle, as
shown.
Installation of the range must be planned so that the rough-
in of the terminal block for the receptacle will allow
maximum clearance to the rear of the unit. To minimize
binding when the unit is connected to the receptacle or
terminal block, orient the receptacle and slide back into
position.
When the power supply cord is connected to the mating
receptacle, the combined plug/receptacle connection
should protrude no more than 2'' (51 mm) from the rear
wall.
Technical Details
15 A
120 V
60 HZ
120V-3 Prong
72" (1829 mm)
Figure 5: Wall Connection