3. Attach the (additional) input (5) or output module (4) to the tie
rods (6).
– Make sure the seals (3) have been correctly inserted and
that the contacts have been properly connected.
4. Retighten the E end plate (2) after the last input module (5)
or output module (4) (2 hexagonal socket-head screws
DIN 912–M4 (1), wrench size 3). Tightening torque: 2.5 to
3 Nm.
5. Establish the connections (see "Connecting bus coupler logic
and load supply" on page 95).
6. Adjust the configuration (see "Configuring the bus coupler
with WinDP" on page 111).