Allows you to adjust the generator's various protection parameters:
• Start protection with password;
• Over- and undercurrent protection;
• Over- and under voltage protection;
• Over- and under frequency protection;
• Overload and low battery charge protection
• High temperature protection;
• Low oil pressure protection;
• Starting failure protection;
• Shutdown failure protection.
C.
Description of the buttons
5
1
8
3
6
USING THE GENERATOR
1.
BEFORE TURNING ON THE GENERATOR
Carefully check the electrical connections and make sure the generator and the equipment to be powered are
properly grounded. If you have any questions, consult a qualified electrician with knowledge of the equipment.
Contact Customer Service for any additional information.
After checking all the electrical connections both from the generator and from the automatic transfer switch
(ATS), if purchased, with regard to the load to be carried, turn the ignition key to the "ON" position.
1. "START" BUTTON: performs the start-up of the generator when in the "OFF"
state.
2. "STOP" BUTTON: performs the shutdown of the generator when in the "ON"
state; alternates between the "AUTO" and "MANUAL" modes of the "automatic
transfer switch" - ATS (turns this function on and off).
3. "MENU/CONFIRM" BUTTON: accesses the configuration sublevels; saves the
changes; cancels the alarm; returns to the previous level.
4. "AUTOMATIC" BUTTON: changes to the "AUTOMATIC" mode when in "MANU-
AL" mode (turns on the ATS function).
2
5. "UP" BUTTON: increments parameter or navigates upward;
6. "DOWN" BUTTON: decrements parameter or navigates downward;
7
7. "RIGHT" BUTTON: moves to the right;
8. "LEFT" BUTTON: moves to the left; enters the submenu; changes the content
4
of the screen.