CARE AND MAINTENANCE
WARNING: Always disconnect pump from power source
before handling.
At least every three months inspect and test
operation:
1.. Check to be sure green 'system ready' light is on
(indicates AC power is on and there are no alarm
conditions)
2. Test for operation:
A. Unplug primary pump and controller.
Fill basin with water to the 'on' level of the backup
pump and allow the pump to run for several
minutes.
NOTE: The alarm will sound approximately one
second after the pump starts to run.
B. Push the Silence/reset button - the alarm will shut
off. The pump will shut off after the water level is
lowered and the float drops to the 'off' position.
Hold the Silence/reset button for three seconds
to reset the controller and clear any alarms or
indicators
C. Plug the controller and the primary pump into the
115V outlet. The primary pump will turn on and
then off when water reaches normal level.
The pump will continue to run after the float is
lowered or until the controller senses water is
being pumping. The four circle lights will be blue.
The battery light will flash slowly after the test as
it recharges the battery. The lights will turn green
once the battery is recharged.
21
© 2020. All rights reserved.
2A
2C
1
2B
by
AC
FLOAT
POWER
STATUS
TEST
24/7 BASEMENT
PROTECTION
DC
BATTERY
PUMP
SILENCE
USB
DC POWER
1-800-584-8089
DC
FUSE
+ 15V DC 1.6A
BasementSentry.com
RESET
FLOAT
PUMP
30 AMP
2A

Publicidad

loading