data and type plate. Use of an extension
cable is prohibited.
DANGER
Danger of electric shock
Danger of death
Avoid damaging the power cables by driv-
ing over them or otherwise crushing them,
or by jerking them.
Protect the cables from heat, oil and sharp
edges.
Check the mains connection of the device
for damage every time before operation.
Do not operate the device using a damaged
cable. Have any damaged cables replaced
by a qualified electrician.
Symbols on the device
Vacuum cleaner labelling
Do not suction up smouldering
dust or other sources of ignition.

Description of the unit

See graphics page for illustrations
Illustration A
Equipotential bonding cable
1
Suction hose connection
2
Collection container
3
Bag filter
4
Cover
5
Gauge
6
Equipotential bonding cable
7
Push handle
8
Power switch
9
Mains cable
10
Steering rollers with parking brake
11
Accessory holder
12
Angular outlet
13

Initial startup

See graphics page for illustration
1. Bring the device into the working posi-
tion.
2. If necessary, secure the device using the
parking brake.
3. Ensure that the suction head is fitted
correctly.
12
4. Insert the suction hose into the suction
hose connection.
Illustration B
5. Plug the desired accessory onto the suc-
tion hose.
See graphics page for illustrations
1. Plug the mains plug into the socket.
2. Switch on the device using the device
switch.
Illustration C
3. Start vacuuming.
Cleaning the dust filter
See graphics page for illustration
Note
Clean the filter regularly to avoid declining
suction power.
Illustration D
1. Move the filter cleaning handle back and
forth several times to clean the filter.
Reading the minimum volumetric
A gauge is mounted on the front of the de-
vice that shows the vacuum intensity.
(see chapter Description of the unit)
The table shows the maximum vacuum in-
tensity value. This value depends on the
unit performance and the suction hose
used.
ATTENTION
Suction loss
If the specified value is exceeded, the air
speed in the suction hose drops below
20 m/s.
Clean the bag filter when the value is
reached, or sooner.
If cleaning does not significantly lower the
value, change out the bag filter.
(see chapter Replacing the bag filter)
Power
Hose di-
ameter
6.0 kW
DN 50
6.0 kW
DN 70
 Clean the filter before or when the spec-
ified value is reached.
English

Operation

flow
Value
230 mbar (23 kPA)
165 mbar (16.5 kPA)