Electrical connection
Mains voltage
Phase
Power frequency
Degree of protection
Protection class
Nominal power
Power protection (slow-
blowing)
Dimensions and weights
Typical operating weight
Length x width x height
Ambient conditions
Ambient temperature
Device performance data
Tank content
Air quantity
Air flow volume during op-
eration
Vacuum
Operating pressure
Nominal width of the suc-
tion hose
Determined values in acc. with EN 60335-2-69
Hand-arm vibration value
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Mains cable
Mains cable H07BQ-F
Part number (EU)
Cable length
Subject to technical modifications.

Technical data

IVR
40/15
Sc
V
400
~
3
Hz
50
IPX4
I
W
1500
A
16
kg
116
mm
870 x
710 x
1530
°C
+40
l
40
l/s
58
l/s
37.5
kPa
20
(mbar)
(200)
kPa
16
(mbar)
(160)
DN50 DN50 DN50 DN50 DN50 DN50 DN50
2
m/s
< 2.5
2
m/s
0.2
dB(A) 63
pA
dB(A) 2
2
mm
4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5
9.979-
856.0
m
7.5
English
IVR
IVR
IVR
40/30
50/15
50/30
Sc
Sc
Sc
400
400
400
3
3
3
50
50
50
IPX4
IPX4
IPX4
I
I
I
3000
1500
3000
16
16
16
131
139
154
855 x
855 x
855 x
715 x
760 x
760 x
1530
1675
1675
+40
+40
+40
40
50
50
87.5
58
87.5
56.5
37.5
56.5
26
20
26
(260)
(200)
(260)
21
16
21
(210)
(160)
(210)
< 2.5
< 2.5
< 2.5
0.2
0.2
0.2
62
57
62
2
2
2
9.979-
9.979-
9.979-
856.0
856.0
856.0
7.5
7.5
7.5
IVR
IVR
IVR
50/40
100/30
100/40
Sc
Sc
Sc
400
400
400
3
3
3
50
50
50
IPX4
IPX4
IPX4
I
I
I
4700
3000
4700
32
16
32
179
159
184
855 x
915 x
915 x
760 x
760 x
760 x
1795
1975
2095
+40
+40
+40
50
100
100
137.5 87.5
137.5
88.5
56.5
88.5
14
26
14
(140)
(260)
(140)
11.5
21
11.5
(115)
(210)
(115)
< 2.5
< 2.5
< 2.5
0.2
0.2
0.2
71
62
71
2
2
2
9.981-
9.979-
9.981-
557.0
856.0
557.0
7.5
7.5
7.5
19