Never vacuum up the following
materials:
– Explosive or combustible
gases, liquids and dust parti-
cles (reactive dust particles)
– Reactive metal dust particles
(such as aluminium, magne-
sium, zinc) in combination
with highly alkaline or acidic
detergents
– Undiluted, strong acids and
alkalies
– Organic solvents (such as
petrol, paint thinners, ace-
tone, heating oil).
In addition, these substances
may cause the appliance materi-
als to corrode.
Hazard levels
DANGER
Pointer to immediate danger,
which leads to severe injuries or
death.
WARNING
Pointer to a possibly dangerous
situation, which can lead to se-
vere injuries or death.
CAUTION
Pointer to a possibly dangerous
situation, which can lead to mi-
nor injuries.
ATTENTION
Pointer to a possibly dangerous
situation, which can lead to
property damage.

Description of the Appliance

 Illustrations on fold-out page 4!
1
Power cord with plug
2
ON/OFF switch for appliance
3
Appliance flap
4
Carrying handle
5
Opening button for appliance flap
6
Defoamer liquid (FoamStop)
7
Upholstery nozzle
8
Storage holder for floor nozzle
9
Accessories flap
10 Accessory mount
11 Crevice nozzle
12 Outgoing air flap for HEPA filter
13 HEPA-filter
14 Water filter container
15 Baffle plate
16 Lid of the water filter container
17 Intermediate filter
18 Floor nozzle, reversible
19 Release to adjust the telescoping vacuum pipe
20 Telescopic suction pipe
21 False air slide
22 Handle
23 Suction hose
Additional scope of supply with appliance
1.195-202.0
24 Turbo floor nozzle

Commissioning/ Operations

Caution! When the water tank is filled, the appliance
may only be operated in the horizontal position. Pri-
or to moving the appliance into the upright position,
the water tank must be drained. Otherwise the floor
can be damaged.
Note
Should the mains fuse trip upon switching on the appli-
ance, it could be due to the fact that other electronic de-
vices are simultaneously connected and operated on
the same electric circuit. Refer to chapter "Technical da-
ta" for mains fuse.
The appliance will shut down automatically if there is
risk of overheating. Turn the appliance off and pull the
power plug. Replace the HEPA filter. After the elimina-
tion of the disturbance, allow the appliance to cool down
for a at least 1 hour; then the appliance is ready for op-
eration again.
Connect accessories
Illustration
 Connect suction hose to the appliance.
 Connect the handle to the telescopic vacuum pipe
and attach the floor nozzle.
Illustration
 Activate the release and extend or retract the inte-
rior pipe to the desired length.
Note: Adjust the telescoping pipe matching your
height so that you will be able to work comfortably
while walking upright.