Maintenance And Care; Technical Specifications - Kärcher DS 5.800 Manual Del Usuario

Ocultar thumbs Ver también para DS 5.800:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Transport, storage
Caution
Prior to storing the appliance, ensure that no water re-
mains in the water filter container and all parts of the wa-
ter filter system are properly dried.
 Hold the appliance at the carrying handle when you
want to transport it and store it in dry rooms.
Illustration
 The appliance can be stored in an upright position.
On the bottom of the appliance there is an addition-
al parking position for the floor nozzle.

Maintenance and Care

Cleaning/replacing the intermediate filter
Note: Clean the intermediate filter at least every 8
weeks with normal use. If the suction performance is de-
teriorating, the filter must be cleaned sooner.
Use a commerically available soft household sponge to
clean the filter to avoid damaging the coated fins.
Illustration
 The individual fins of the intermediate filter can be
cleaned under running water using the sponge.
 Allow the filter to dry completely.
 With normal use, replace the intermediate filter at
least every 12 months, if necessary, it can be re-
placed sooner.
Note: The intermediate filter must be disposed off
as residual waste.
Cleaning the appliance and accessories
Illustration
 Suction hose and handle can be disassembled for
cleaning.
 Check the accessories for obstructions and clean if
necessary. Do not use water to clean the floor noz-
zle.
Clean the turbo floor nozzle
* depending on model
Cut hair that is entangled in the roller brush along the
cutting edge with a pair of scissors, and vacuum them
off using the crevice nozzle.
Change HEPA filter
Note: In order to ensure an optimised cleaning perfor-
mance and function of the appliance, this filter must be
changed at least every 12 months. Replace sooner if
damaged or extremely dirty.
Caution
Do not rinse out the HEPA filter!
 Remove the outgoing air flap.
Illustration
 Remove the HEPA filter.
 Insert a new HEPA filter so that it "CLICKS" into
place.
 Reinstall the lid so it "CLICKS" into place.

Technical specifications

Nominal voltage
1~50-60 Hz
Output P
nom
Fill capacity of the water filter
reservoir
Sound
Weight (without accessories)
Nominal width, accessories
DS 6.000 Waterfilter
DS 6.000 Waterfilter, Mediclean:
HEPA filter H 13 class according to EN 1822 (effective
1998)
DS 5.800 Waterfilter:
HEPA filter H 12 class according to EN 1822 (effective
1998)
Subject to technical modifications!
– 9
EN
220-240 V
900 W
2,0 l
66 dB(A)
7,5 kg
35 mm
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ds 6.000

Tabla de contenido