Description Of The Inspection And Servicing Work - GG PP40 Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10.5

Description of the inspection and servicing work

Checking the hydraulic oil level in the tank
It must be checked at regular intervals that there is sufficient hydraulic oil in the hydraulic oil tank (9
or 23). To do this, follow this procedure:
-
Ensure that the hydraulic cylinder (12 or 27) is in the low-end position.
-
Decommission the machine (see Chapter 8 Operation).
-
Open bleed valve (8 or 24), which is on the hydraulic oil tank.
-
Use a measuring aid to measure the fill level of the hydraulic oil tank. There should be
approximately 2 - 3 cm of air space between the hydraulic oil level and the upper tank wall.
-
If necessary, top up using HLP46 hydraulic oil.
-
Close the tank using the bleed valve (8 or 24).
8 or 24
2 - 3 cm
9 or 23
Original operating manual packing presses
10.07.2017
Maintenance
Page 60 of 123
English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pp80Pp150

Tabla de contenido