2 INSTALLATION

2.1 FIXED CIRCUIT BREAKER

„ Fasten the circuit breaker by the side supports - (4x) M12

2.2 DRAW -OUT CIRCUIT BREAKER

„ Fasten the extraction car from inside - (4x, 6x, 8x) M12;
„ Pull the rails of both sides as far out as far as possible;
„ Position the circuit breaker on the rails, paying attention to the perfect fit;
„ Slowly push the circuit breaker inside the extraction car, until it reaches the end.
28 | ABW - Air Circuit Breaker
(4x) M12
40-50 Nm
Figure 2.1: Fixed circuit breaker
Circuit breaker
fitting guide
Rail guide
pin
Figure 2.2:Draw -out circuit breaker