9.1. Routine maintenance
OFF
Before
GB
disconnect the power supply and make sure
that the device could not accidentally operate.
In the case of water containing chloride
(chlorine, sea water), the risk of corrosion
increases in stagnant water condictions (also
with an increase in temperature and decrease
of pH value). In these cases, if the pump
remains inactive for long periods, it must be
emptied completely and, preferably, dried.
For good measure, as in the case of temporary
operation with dirty liquids, run the pump
briefly with clean water to remove deposits.
When the pump remains inactive it must be
emptied completely if there is a risk of freezing
(par. 14 fig. 5).
Before restarting the unit, check that the shaft is not
jammed and fill the pump casing completely with liquid.
9.2. Vessel maintenance
Inspect the tank preloaded pressure of the delivery
vessel periodically.
9.3. Dismantling the system
Close the suction and delivery gate valves and drain
the pump casing before dismantling the pump.
12. ALARMS
Code
Description
Er01
Blockage due to no water
Er02
Pressure transducer fault
Er03
Blockage due to low supply voltage
Er04
Blockage due to high rectified voltage
Er05
Blockage due to exceeded of number of starts
Er06
Blockage due to overpower in the electro pump
Er07
Blockage due to overcurrent in the electro pump motor
Er08
Blockage due to internal overheating
Er10
Thermal-protector intervention detected
Er11
Internal hardware error
Page 14 / 60
every
maintenance
9.4. Dismantling the pump
OFF
Close the suction and delivery gate valves and drain
operations
the pump casing before dismantling the pump (par. 14
fig. 5).
10. DISPOSAL
OFF
The final disposal of the device must be done by
specialized company.
Make sure the specialized company follows the
classification of the material parts for the separation.
Observe the local regulations and dispose the device
accordingly with the international rules for environment
protection.
11. SPARE PARTS
11.1.
When ordering spare parts, please quote their
designation, position number in the cross section
drawing and rated data from the pump name plate
(type, date and serial number).
The spare parts request shall be sent to CALPEDA
S.p.A. by phone, fax, e-mail.
Changes reserved.
Causes
The device is in failure due to no water.
The system try to restart automatically and make one attempt
every 10 minutes for 6 times.
Pressure transducer spoiled
Supply voltage lower than 195V.
- The system automatically restart when the clamp voltage is
higher than 205V.
Supply voltage higher than 225V.
- The system automatically restart when the clamp voltage is
lower than 225V.
The system has started more than 240 times in 2 hours
The system try to restart automatically and make one attempt
every 10 seconds for 3 times.
Motor overheating
E-MXAM E-MXPM Rev1 - Operating Instructions
European Directive
2012/19/EU (WEEE)
Spare-parts request