Technical Data; Electrical Data Input; Electrical Data Output; Mechanical Data - Fronius Acctiva Seller Manual De Instrucciones

Ocultar thumbs Ver también para Acctiva Seller:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83

Technical data

Electrical data
Mains voltage
input
Mains frequency
Mains current
Mains fuse protection
Efficiency
Effective power
Power consumption (standby)
Protection class
Maximum permitted mains impedance at the interface (PCC) to the public grid
EMC emission class
Electrical data
Nominal output voltage
output
Output voltage range
Output current
Battery return current

Mechanical data

Cooling
Dimensions l x w x h
Weight (without cable)
Environmental
Operating temperature
conditions
Storage temperature
Climate class
Degree of protection, horizontal position
Degree of protection, vertical position

Standards

EN 60068-2-6, Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; acceleration 5 g)
EN 60068-2-6, Sinusoidal vibration (sine 10-150 Hz; 20 cycles / axis; acceleration 2 g)
EN 60068-2-29, Repetitive Shock (1000 shocks at 25 g / 6 ms per axis)
EN 60335-1
EN 61000-3-2
EN 61000-6-2
EN 61000-6-4
All manuals and user guides at all-guides.com
EN 60335-2-29
(EN 61000-4-2, EN 61000-4-3, EN 61000-4-4)
(EN 61000-4-5, EN 61000-4-6, EN 61000-4-11)
(Class A)
13
~ 230 V AC
50 / 60 Hz
max. 2.9 A eff.
max. 16 A
max. 95 %
max. 420 W
max. 1.7 W
12 V DC
2 V – 16.8 V DC
30 A at 13.5 V DC
Convection
270 x 168 x 100 mm
10.63 x 6.61 x 3.94 in.
-20 °C - +40 °C (>30 °C derating)
-4 °F - +185 °F (>86 °F derating)
-40 °C - +85 °C
-40 °F - +104 °F
I
none
A
< 1 mA
2.2 kg
4.85 lb.
B
IP40
IP44

Publicidad

Tabla de contenido
loading