Specifications
MODEL NUMBER:
Continuous Power (@ 20° C):*
Double Boost™ Peak Surge Power:*
DC Input Volts (Nominal):
DC Input Voltage Range:
DC Input Connection:
Output Volts (Nominal):
Output Frequency (Nominal):
Efficiency:
Output Waveform:
* DoubleBoost duration (instantaneous). Actual output depends on battery age, battery charge level and ambient temperature.
Minimum Recommended Cable Sizing Chart
Always loosely twist each pair of cables (one positive and one negative) together. Use in conjunction with DC wiring
connection instructions in the Battery Connection section. Using 4 conductors is recommended (but not required) to
obtain maximum output power from PV3000HF models.
2 Conductors (all models)
Watts
6
500
15 ft
700
11 ft
1000
N/R
2000
N/R
2400
N/R
3000
N/R
† N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the
performance)
Tripp Lite Inverters include a Battery Charge Conserver (Load Sense) Control which saves battery power by
allowing users to set the minimum load level at which the unit's inverter turns on. Users can significantly
reduce the No Load DC Input Current to a very low amperage power level with the use of this control.
PV1000HF
1000 Watts
2000 Watts
12 VDC
10 - 15 VDC
User Supplied Cables
120 VAC
60 Hz, ± 0.5%
Up to 94%
Modified Sine Wave
†
4
2
0
25 ft
39 ft
62 ft
18 ft
28 ft
44 ft
12 ft
20 ft
31 ft
N/R
N/R
16 ft
N/R
N/R
13 ft
N/R
N/R
10 ft
PV1800HF
1800 Watts
3600 Watts
12 VDC
10 - 15 VDC
User Supplied Cables
120 VAC
60 Hz, ± 0.5%
Up to 94%
Modified Sine Wave
Wire Gauge
4 Conductors (PV3000HF only)
00
79 ft
56 ft
39 ft
20 ft
16 ft
13 ft
12
PV3000HF
3000 Watts
6000 Watts
12 VDC
10.5 - 15 VDC
User Supplied Cables
120 VAC
60 Hz, ± 0.5%
Up to 94%
Modified Sine Wave
Twin 00
158 ft
112 ft
78 ft
40 ft
32 ft
26 ft