6
ELECTRICAL INSTALLATION
en
7

Commissioning

7.1

Alignment

18
O P E R A T I N G I N S T R U C T I O N S | WTB4S-3
Table 7: DC
WTB4S-3
x1361
1 = BN
+ (L+)
2 = WH
-
3 = BU
- (M)
4 = BK
Q
0.14 mm
Switching behavior
Figure 8: Switching behavior
WTB4S-3Exxxx and WTB4S-3Fxxxx.
D: dark-switching, output (Q) switches off when an object is present in the sensing
range.
WTB4S-3P1362, WTB4S-3Px1xx, WTB4S-3N1362 and WTB4S-3Nx1xx:
L: light switching, output (Q) switches when an object is present in the sensing range.
WTB4S-3P1161, WTB4S-3N1161, WTB4S-3Px261 and WTB4S-3Nx261:
ANT: complementary outputs Q and Q/
Align the sensor with the object. Select the position so that the red emitted light beam
hits the center of the object. You must ensure that the optical opening (front screen) of
the sensor is completely clear [see
We recommend making the adjustments using an object with a low remission.
-P/-N1161
x3161 / x2161
+ (L+)
Q
- (M)
Q
3
2
0.14 mm
2
4
figure
9].
-P/-N3261
-P/-N2261
+ (L+)
+ (L+)
-
Q
- (M)
- (M)
Q
Q
1
3
4
8027693.1E52/2022-03-21 | SICK