Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
7

Commissioning

7.1
Check the application conditions
8027085/2022-05-31 | SICK
Subject to change without notice
Check the application conditions: Adjust the mounting position so that the sensing
range and remission capability are within the maximum sensing range, which is 45 mm
on black. During this process, an object can only be detected in front of a background if
the remission capability of the object is significantly higher than that of the background
or if the distance between the object is sufficient.
NOTE
Observe the minimum sensing distance of 2 mm.
Operating reserve
1,000
100
10
1
0
50
(1.97)
Figure 6: Operating reserve
Sensing range on black, 6 % remission
1
Sensing range on gray, 18 % remission
2
Sensing range on white, 90 % remission
3
Blue
Recommended sensing range
area
Active beam width:
OPERATING INSTRUCTIONS
100
150
(3.94)
(5.91)
Distance in mm (inch)
O P E R A T I N G I N S T R U C T I O N S | RSB - Roller Sensor Bar
en
35

Publicidad

Tabla de contenido
loading

Tabla de contenido