CONNECTING THE BATTERY CHARGER

The unit is set up to provide for automatic
battery recharging. If this function is to be
used, proceed as follows.
Use a cable of the section indicated in
the table, and connect it to the relevant
terminal on the generator and to the
positive terminal of the battery to be
CONNECTING THE FUEL INDICATOR
Only use the indicator connection if there
is a fuel level probe in the tank used for the
generator.

CONNECTING THE BATTERY

To start the generator it is necessary to
use a 12VDC battery, with a minimum
capacity of 60Ah.
Use regulation, sheathed cables, with the
section indicated in the table, and follow
the working order given below:
First connect the positive cable (+ ) of the
battery to the terminal marked with the
symbol "+ " on the generator.
ELECTRICAL CONNECTION TO THE EXTERNAL NETWORK
Important
To use electric power from the external
network, follow the instructions given
below with care.
The on board electrical system must be
fitted with a relay or switch (e.g. switch
cod. AG113, available on request) to
prevent damage to the generator when
the external power supply network is
connected; in this case, it is suggested
that the generator be connected in such a
way as to give it priority with respect to the
external network.
All manuals and user guides at all-guides.com
charged.
If the battery to be charged is not the one
used to start the generator, the negative
terminal of that battery must be connected
to the generator mass point.
Connect the proble cable (e.g. float) to the
relevant terminal (see figure above).
Then connect the negative cable (-) of the
battery to the terminal marked with the
symbol "-" on the generator.
Protect the connections with specific
grease.
It is advisable to use a 100A fuse, series
fitted in the vicinity of the starter battery
positive terminal, so as to protect the unit
system.
The electrical connection must be made
in compliance with current laws in the
country of use.
For proper installation by the end user,
it is recommended that you request the
technical assistance of the dealer or a
specialist technician.
For the 230 V, use an approved cable
with the section indicated in the table. For
connection of the switch cod. AG113 refer
to the instructions and diagram on the
following pages.
-
-