Information On Spare Parts - Dometic ENERGY & LIGHTING TEC Serie Instrucciones De Montaje Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 102
Alarm
RESTART GEN?
GEN CAL
GEN WAIT
GEN ON
GEN OFF
RECOMMENDATIONS WHEN CHANGING PARTS
Before replacing any parts, activate all the
safety devices provided and evaluate the
need to inform the persons working on the
machine and any persons in the vicinity.
In
particular,
make
surrounding areas are adequately marked
and prevent access to any of the devices
that might, if active, result in unexpected
dangers and risks to the health and
CHANGING THE WATER PUMP ROTOR
Proceed as indicated.
1 -Switch the appliance off
and leave it to cool.
2 -Unfasten the screws to
dismantle the casing (M).
3 -Unfasten the screws to
remove the cover (N).
4 -Extract and replace the
rotor (P).
5 -Fit the cover (N) and fix it
with the screws.
6 -Fit the casing (M) and fix
it with the screws when
this operation has been
completed.
All manuals and user guides at all-guides.com
Cause
Unit overheating
The unit is performing automatic setup
prior to starting
The unit is paused before starting
Unit running
Unit off or ready for START

INFORMATION ON SPARE PARTS

sure
that
the
casing (M)
-
33
Remedy
Switch the appliance off and leave it to
cool.
Wait until the operation has ended
then start the unit
Wait until the operation has ended
then start the unit
safety of persons. Should it be necessary
to change worn components, only use
original spare parts.The manufacturer will
not be liable for any damage to persons
or components deriving from the use of
non-original spare parts and from repairs
carried out without the authorisation of the
manufacturer.
rotor (P)
cover (N)
-
GB
User Manual

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Energy & lighting blutec40d

Tabla de contenido