Switching The Data Logger On And Setting Its Basic Parameters - HURNER SPG 2.0 Manual De Instrucciones

Ocultar thumbs Ver también para SPG 2.0:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
on a worksite is only acceptable if the power supply
has earth-leakage circuit breakers.
After connecting the power supply cord to the mains pow-
er supply or a generator, turn the product on at the On/Off
switch.
It has to be ensured that the voltage of the power
source the machine is connected to corresponds to
the rated voltage of the machine. Also the follow-
Caution
ing has to be respected when using extension ca-
bles:
wire section 1.5 mm² = max. 20 m long
wire section 2.5 mm² = max. 75 m long
wire section 4.0 mm² = max. 100 m long
4.1
Switching the Data Logger on and Setting its Basic
Parameters
After the machine was switched on, Display 1 shows on the
screen.
The system will then automatically start the auto-test pro-
cess to check the sensors and the system clock, to determine
the number of free welding reports. This test can be by-
passed by holding down the STOP/RESET key when Display 1
is showing.
If during the auto-test an error is detected, a "Sys-
tem Error" message shows. When this happens, the
data logger has to be disconnected immediately
Caution
from the power supply and the butt-welding ma-
chine and it has to be returned to the manufacturer
for repair.
During the auto-test several screens resembling Display 2
appear. They inform the welder of the currently selected
pressure and temperature sensor, the current outside tem-
perature, power supply voltage, time, and date as well as of
the kind of machine and welding standard selected at that
point. By pressing the MENU key, you can access the Con-
figuration Menu to change all parameters to be applied to
the imminent welding operations which are not currently
selected as they should be.
Then Display 3 appears with the parameters that will be
used for the next welding, including time of day, date, re-
port number, and joint number (the joint number will show
only if this function has been enabled in the Configuration
Menu), along with, in the second-to-last line, the actual in-
put voltage and — if the cable of the heating element for
butt welding is connected — the actual and nominal heat-
ing element temperature before and after the slash. From
10
EN
HÜRNER SPG 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
********************
HUERNER
*
SPG 2.0
*
********************
**** Machine Data ****
HST-355
Cylinder
:
Pres.Sens.:
Next welding
15:44:52
112V
135C/220C
Rep. No. 00072/00002
Version November 2022
*
*
Display 1
06.60
160bar
Display 2
29.05.12
Display 3