press the MENU key to confirm your selection. Under Cali-
brate Pressure Sensor, you can calibrate for connected the
machine, i.e. determine the zero pressure point for the sen-
sor. To do so, move the carriage apart to the farthest point
and then press the START/SET key. The display screen then
shows the reference pressure, e. g. 80.0 bar if the 160 bar
pressure sensor is currently selected (see Display 7). The
displayed reference pressure, which is not the same for all
available pressure sensors, has to be set on the machine us-
ing its pressure gauge, and the display value, to be adjusted
accordingly using the ñ or ò cursor keys. By pressing the
START/SET key, the data are saved to the system.
The heating element can be calibrated under the Calibrate
Heating Element option. Use the ñ or ò cursor keys and the
START/SET key in the same manner.
When matching the displayed value to the refer-
ence using the ñ and ò keys, holding the respective
key down will make the values change faster.
Info
4.1.1
Configuring the Fundamental Operating Settings of the Machine
In the sub-menus of the configuration menu, at "Settings,"
the parameters related to the logger itself and its operation
can be set. At "Recording," the traceability data that have
to or need not be recorded and written into the reports can
be enabled or disabled. The desired sub-menu is selected
using the ñ and ò cursor keys. Then, to access that sub-
menu, press the MENU key.
In both parts of the configuration menu, use the ñ and ò
keys to select the desired set-up option. Use the ð cursor
key to toggle between "on" and "off" for that option.
If a "M" is shown next to a set-up option, this indicates that
a sub-menu is accessible here by pressing the MENU key.
On both menu levels (Configuration Menu and its
respective sub-menus), press the START/SET key to
save the settings to memory or press the STOP/RE-
Important
SET key to return to the previous menu level with-
out saving possible changes.
4.1.2
Understanding the "Settings" Sub-menu
"Check Code Expiry on" means that the welder identifica-
tion code has to be current and not expired (default pe-
riod of validity 2 years from code issuance), or the weld-
ing operation cannot be started, "off," that the validity
of the code is not checked at all.
"Memory Control on" means that when the system memory
is full of reports, the system will be blocked until the
reports are printed or downloaded, "off," that it works
but that the oldest report will be overwritten.