Type of Error
b. System and Conditions
System Error
Clock Error
Power Supply Failure at
Last Welding
Ambient Temperature
High
Ambient Temperature
Low
Pressure Sens. Defective The sensor indicated on the display (hydraulic pressure,
Heating Sens. Defective
Temperature Sensor
Defective
Printer not Ready
(only label tag printer)
Download Cancelled
Memory Full
c. Welding Process
Temperature low
Temperature high
Error Changeover
Error Drag Pressure
Error Build-up Pressure
Error Heat Soak
Pressure
Error Joining Pressure
Cooling Stopped
Error Plate Temperature Heating element temperature is out of tolerance;
Version November 2022
The data logger has to be disconnected immediately from
both the power supply and the welding system. The auto-
test has detected an error in the system. The logger must
no longer be operated and has to be sent to an approved
shop for check and repair.
The internal clock of the logger is defective; re-set the
clock in the configuration menu.
The last welding is incomplete. The welding system was
disconnected from the power supply voltage while it was
in progress. To go on using the product, this error has to
be acknowledged by pressing the STOP/RESET key.
Outside temperature not within the range from – 20°C
to + 60°C.
Outside temperature not within the range from – 20°C
to + 60°C.
heating element temperature, ambient temperature) is
defective; where possible, check the connections/plug;
have the machine inspected by an authorized service shop
if needed.
The optional printer is not ready (possible reasons also: no
communication or faulty cable).
During data transfer or printing, an error condition
occurred which could not be cleared.
The system memory is full of welding reports. Print or
download the reports in memory or switch memory
control off. Without memory control, a new report
overwrites the oldest existing one.
The heating element temperature will be increased
automatically.
The heating element temperature will be reduced
automatically.
It took too long to retract the heating element and bring
the pipes to joining; welding will have to be repeated.
Impossible to determine the drag pressure; maybe pipes
will have to be clamped once again; or the pressure is
below 1 bar, which is not feasible for technical reasons.
The build-up pressure is too high or too low and was not
re-adjusted in time.
The heat-soaking pressure is too high and was not
re-adjusted in time.
The joining pressure is too high or too low and was not
re-adjusted in time.
Operator has stopped the cooling time by pressing the
STOP/REST key.
impossible to re-adjust the temperature; maybe the
ambient temperature was too low.