True RMS Thermal MultiMeter / English
4.18.Capturing Peak Values
To activate the peak mode, press the soft key labeled .
If the Meter is already in the peak function, press
to turn off peak.
4.19.Non-Contact AC Voltage Detector (100 to 1000V AC)
WARNING: Risk of Electrocution. Before use, always test the Voltage
Detector on a known live circuit to verify proper operation.
WARNING: Insulation type and thickness, distance from the source, and
other factors may effect operation. Always verify live voltage using
other methods before working on electrical circuits.
• The non-contact voltage detector operates when the meter is set
to any measuring function. The detector does not operate when Auto
Power Off turns the meter off or when the rotary function switch is
set to the off position.
• Slowly move the detector probe closer to the conductor being tested.
• If AC voltage within the specified range is present, the indicator light
will illuminate.
NOTES: The detector is designed with high sensivity. Static electricity and other sources of electrical
energy may randomly activate the detector. This is normal operation. The detector only activates the
indicator light when AC voltage is present.
It does not indicate the voltage level on the LCD display.
14
causes the Meter
19/07/2018 Version No. 001
5.Thermal imager and DMM opertion
5.1.Thermal imager basics
In the Thermal imaging and DMM mode. User can mearsure a targeted surface's temperature and user
can use Mutimeter at the same time, the measured result will display under the themal image.
• Press the red "IR" button to open the Thermal Imager. In Fig5-1 the thermal image is set to color
palette IRON. Select other palettes in the Menu Settings.
• Open the protective lens cover on the back of the meter.
1.The Battery capacity indicator.
2.SD card icon, if this icon is displayed, there is a SD card inserted.
3.Bluetooth icon, if this icon is displayed, the BlueTooth is opened.
4.The currently selected Emissivity value. Use the Thermal Settings Menu to change the emissivity value.
5.The temperature unit icon, Use the Thermal Settings Menu to select "
6.Current time Display
7.Center cross of the Thermal imager Temper ture Measurement, represents the center spot temperature
of the scene.
8.Highest temperature spot of the Thermal imager Temper ture Measurement, represents the highest
spot temperature of the scene.
9.Minimum temperature spot of the Thermal imager Temperture Measurement, represents the
Minimumspot temperature of the scene.
10.Current scene ot theThermal image frame
11.Range icon of the meter
12.Max soft button
13.REL soft button
14.PEAK soft button
15.DMM measurement is shown below the thermal image.
16.Unit of the meter
17.Lowest reading measured in the current frame
18.The Thermal scale shows the range color for thermal images, The lighter the color, the warmer the
temperature; The darker the color, the cooler the temperature.
19.Highest reading measured in the current frame.
19/07/2018 Version No. 001
True RMS Thermal MultiMeter / English
o
o
C",
F, K.
15