1. Connect the connection cable (Pos. 4) to the control box (Pos. D) or
transformer box (Pos. E). To do this, insert the connector plug (Pos. 4.1.)
into the connection socket provided.
2. Lay the connection cable (Pos. 4) to the stationary filter unit (Pos. C).
3. Drill a Ø 8 mm [Ø 0.31 inch] hole at the back of the slewing ring.
4. Pull the connecting cable through the slewing ring.
5. For further steps see chapter: Cable routing + connection of the
extraction hood with lighting + retrofit control box transformer.
5.5.3 Control Box - Retrofit Transformer
Pos.
Description
D
Control box
11
Transformer
1. Switch off the control box (Pos. D) and disconnect it from the mains.
2. Open the control box (Pos. D) by removing the cover plate.
3. Attach the transformer (Pos. 11) to the base plate of the control box (Pos.
D). Use the enclosed fixing material for this purpose.
4. Insert the connector plug (Pos. 11) into the connection socket (Pos. 12).
1502759-03
Fig. 46: Control Box - Retrofit Transformer
Tab. 47: Positions on the product
- 81 -
Pos.
Description
12
Connector plug
13
Connection socket