5.3 Control elements

On the front side of the CleanAirTower device there are controls and connections:
-
I / 0 button (pos. 1)
Press this button to turn the device on and off.
The green ring around the switch indicates faultless operation of the system.
In case of failure, or error the green light goes out.
The device switches off automatically.
If the light ring is flashing, the device is in the cleaning status.
-
Signal light (pos. 2)
Yellow warning light indicates a failure or instrument fault. These faults are
visually represented by different flashing codes.
Signal light flashes evenly at regular intervals:
- It is necessary to service the equipment, please inform the KEMPER
service.
Signal light flashes 2 times shortly in succession at regular intervals:
- If a failure of the frequency converter occurs, inform of it the KEMPER
service department.
Signal light flashes 4 times shortly in succession at regular intervals:
- Compressed air failure, check for sufficient supply of compressed air.
-
Manual dust removal (pos. 3)
This switch can be used to run on the manual dust removal. The system can
be turned off by depressing the switch again.
-
"IFA" measuring connection (pos. 4)
Intended only for KEMPER service.
-
Service terminal (pos. 5)
Connection for KEMPER service. Through this interface the KEMPER service
can perform pressure measurements.