from the group flowmeter when coffee
is being dispensed from group 1.
Probable causes are:
• Flowmeter is locked
• Flowmeter connecting cable is not
properly connected
Consequences:
• Anomaly is signaled
Dispensing will be locked depending on
the time that has been set during dose
set up.
ALC 02
This alarm concerns group 2.
ALC 03
This alarm concerns group 3.
ALT 01
This alarm triggers three minutes after
pressing the manual free doses button
of group 1 without switching it off.
Probable causes are:
• User's negligence
All manuals and user guides at all-guides.com
Consequences:
• Anomaly is signaled and dispensing
locked. To cancel the alarm, press
the CANC button below the display
ALT 02
This alarm concerns group 2.
ALT 03
This alarm concerns group 3.
ALM 01
This alarms triggers when the pre-set
number of cycles of group 1 solenoid
valve is reached. To cancel the alarm,
press the CANC button below the
display
ALM 02
This alarm concerns the cycle counter
of group 2 solenoid valve.
ALM 03
This alarm concerns the cycle counter
of group 3 solenoid valve.
ALM 05
This alarm concerns the cycle counter
of the pump.
ALM 06
This alarm concerns the cycle counter
of the auto-fill solenoid valve.
ALM 07
This alarm concerns the cycle counter
of the tea solenoid valve.
ALM 08
This alarm concerns the cycle counter
of the MCS solenoid valve.
AL SER 01
No serial connection between
electronic display board and power
card.
AL SER 02*
57